Datalogic Scanning PD7100 Barcode Reader User Manual


 
Flash Off Time
Product Reference Guide 39
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The se-
lectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond in-
crements.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result
with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
4. Scan the barcode: SELECT FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that repre-
sent the duration which was determined in the steps above. You will hear a two-
beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See Table 6 for some examples of how to set this feature.
Table 6. Flash Off Time Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP ACTION EXAMPLES
1 Desired Setting 500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.)
2
Divide by 100 (and pad with
leading zeroes to yield two digits)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH OFF TIME SETTING
5
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE