Datamax I-4208 Printer User Manual


 
I-Class 47
System Settings (continued)
PAUSE MODE When enabled, suspends printing between
each label until the PAUSE Key is pressed.
ENABLED
Requires an operator press the PAUSE Key
after each label.
DISABLED
The printer completes label batch without
pausing between labels.
PEEL MODE Specifies that a Feed operation be
prevented when the label is presented and
not removed, or if the printer is to wait for
the GPIO start of print signal.
ENABLED
Feed is inhibited according to the above
criteria.
DISABLED
Feed is always enabled.
SECURITY
Provides the user with the ability to
password protect all printer settings made
through the front panel.
SELECT SECURITY
Enable or disable the menu system’s
security feature.
ENABLED
Password protected.
DISABLED
No protection.
MODIFY PASSWORD
Modify the password required to access the
menu system when security is enabled.
UNITS OF MEASURE Selects the measurement system in which
the system’s settings are represented in the
menu system and on configuration labels.
METRIC
Metric standard: lengths given in
millimeters and counters in centimeters.
IMPERIAL
Inch standard: lengths and counters given
in inches.
INPUT MODE Defines the type of printer language.
DPL
Standard DPL processing.
LINE
Standard DPL processing with addition
Line mode Template processing enabled.
Line Mode exacts data terminated by a
carriage return to be inserted in a DPL
template and printed.