Datamax I-4208 Printer User Manual


 
I-Class 75
Advanced Entry Calibration (continued)
Step Operator Action Displayed Message Comment
13
Using the
Key,
select the Gain Number
determined in Step 12.
Press the
Key to
select the setting.
HBJO!USBO!!!!!!=zzz?
+19!!!!!!!!!)1!.!42*
Or, for reflective media:
HBJO!SFGM!!!!!!=zzz?
+19!!!!!!!!!)1!.!42*
Selection is
denoted with an
‘*’.
14
n Place the media in the
Media Sensor. Record
the sensor reading and
label it ‘P’ (paper).
o Place the backing, mark,
or notch in the Media
Sensor. Record the
sensor reading and label
it ‘G’ or ‘M’ (Gap or
Mark).
p Remove all media.
Record the sensor
reading and label it ‘E’
(Empty).
HBJO!USBO!!!!!!=zzz?
+19!!!!!!!!!)1!.!42*
Or, for reflective media:
HBJO!SFGM!!!!!!=zzz?
+19!!!!!!!!!)1!.!42*
Where ‘yyy’ is
a numerical
value
representing the
current sensor
reading.
15
Press the Key.
Then press the
Key.
BEWBODFE!FOUSZ
TFOTPS!MFWFMT
The sensor
readings must
be manually
entered into the
printer now.