Dell E07S Series Server User Manual


 
28 About Your System
E1410 Internal Error
detected.
Check "FRU X".
Specified processor has an
internal error. The error
may or may not have been
caused by the processor.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
E1414 CPU # temp
exceeding
range. Check
CPU heatsink.
Specified processor is out
of acceptable temperature
range.
Ensure that the processor
heat sink is properly
installed. See
"Troubleshooting the
Processor" on page 160
and "Troubleshooting
System Cooling
Problems" on page 151.
E1418 CPU # not
detected.
Check CPU is
seated
properly.
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
Ensure that the specified
microprocessor is
properly installed. See
"Troubleshooting the
Processor" on page 160.
E141C Unsupported
CPU
configuration.
Check CPU or
BIOS revision.
Processor is in an
unsupported
configuration.
Ensure that your
processor matches and
conforms to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.
E141F CPU # protocol
error. Power
cycle AC.
The system BIOS
has reported a processor
protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
Table 1-2. LCD Status Messages (Optional) (continued)
Code Text Causes Corrective Actions
R310HOM.book Page 28 Thursday, March 4, 2010 1:03 AM