Dell E07S Series Server User Manual


 
44 About Your System
No boot sector on
hard drive.
Incorrect configuration
settings in System Setup
program, or no operating
system on hard drive.
Check the hard drive
configuration settings in the
System Setup program.
See "Using the System Setup
Program and UEFI Boot
Manager" on page 53.
If necessary, install the
operating system on your
hard drive. See your
operating system
documentation.
No timer tick
interrupt.
Faulty system board. See "Getting Help" on
page 169.
PCIe Training
Error: Expected
Link Width is
x
,
Actual Link Width
is
y
.
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number.
See "Troubleshooting an
Expansion Card" on
page 159. If the problem
persists, see "Getting Help"
on page 169.
Plug & Play
Configuration
Error.
Error encountered in
initializing PCIe device;
faulty system board.
Install the NVRAM_CLR
jumper in the clear position
(pins 1 and 3) and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists,
see "Troubleshooting an
Expansion Card" on
page 159.
Quad rank DIMM
detected after
single rank or
dual rank DIMM in
socket.
Invalid memory
configuration.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 106.
Table 1-3. System Messages (continued)
Message Causes Corrective Actions
R310HOM.book Page 44 Thursday, March 4, 2010 1:03 AM