About Your System 39
Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The optional iDRAC6
has hung.
The optional iDRAC6 was
remotely reset while system
was booting.
After AC recovery, the
optional iDRAC6 takes
longer than normal to boot.
Remove AC power to the
system for 10 seconds and
restart the system.
Alert! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The system configuration
of processor,
memory modules,
and expansion cards may
not be supported by the
power supplies.
If any system components
were just upgraded,
return the system to the
previous configuration.
If the system boots without
this warning, then the
replaced component(s) are
not supported with this
power supply. If Energy
Smart power supplies are
installed, replace them with
High Output power supplies
to use the components.
See "Power Supplies" on
page 125.
Alert! System
fatal error
during previous
boot.
An error caused the system to
reboot.
Check other system
messages for additional
information for possible
causes.
Table 1-3. System Messages (continued)
Message Causes Corrective Actions
R310HOM.book Page 39 Thursday, March 4, 2010 1:03 AM