Cabling The Dell EqualLogic PS6000/PS6100/PS6500 Storage Arrays
1. Connect a network cable from the network switch 0 to Ethernet 0 on the control module 1.
2. Connect a network cable from the network switch 0 to Ethernet 1 on the control module 1.
3. Connect a network cable from the network switch 1 to Ethernet 2 on the control module 1.
4. Connect a network cable from the network switch 1 to Ethernet 3 on the control module 1.
5. Connect a network cable from the network switch 1 to Ethernet 0 on the control module 0.
6. Connect a network cable from the network switch 1 to Ethernet 1 on the control module 0.
7. Connect a network cable from the network switch 0 to Ethernet 2 on the control module 0.
8. Connect a network cable from the network switch 0 to Ethernet 3 on the control module 0.
9. Repeat steps 1 to 8 to connect the additional Dell EqualLogic PS6000/PS6100/PS6500 storage array(s) to the iSCSI
switches.
NOTE: For PS6100 storage array, having all eight cables in steps 1 through 4 provides highest level of cable
redundancy. It works fine with only four cables. You can skip either step 1 or 5, either step 2 or 6, either step 3 or 7,
and either step 4 or 8.
For more information, see the figures below.
Figure 15. Cabling an iSCSI SAN-Attached Cluster to a Dell EqualLogic PS6000 Storage Array
1. cluster node 1
2. cluster node 2
3. switch 0
4. switch 1
5. Dell EqualLogic PS6000 storage system
6. control module 1
7. control module 0