Error Code Message Information
LCD Message SBE log disabled on <
location
>. Re-seat memory.
Details Errors are being corrected but no longer logged.
Action Review system logs for memory exceptions. reinstall memory at location <
location
>.
OSE0000
Message A critical stop occurred during OS load.
Details The system halted due to an exception during operating system load or operating system
initialization.
Action Review operating system logs and system video for additional information.
OSE0001
Message A runtime critical stop occurred.
Details The system halted due to an exception while the operating system was running. This is a
kernel panic or bug check event.
Action Review operating system logs and system video for additional information.
OSE0004
Message A soft shut-down initiated by platform event filter.
Details A separate exception or status condition shutdown the operating system. (IPMI sensor type
20h - offset 04h).
Action Review system event log for platform events capable of shutting the system down.
OSE0005
Message Agent is not responding.
Details Graceful shutdown request to an agent via the BMC did not occur due to a system
hardware or software exception.
Action Review operating system logs and system video for additional information.
OSE1001
Message Failed to boot from A.
Action Review system boot configuration and boot media. Verify the media in a: is bootable. See
system video for additional information.
OSE1003
Message Failed to boot from C.
Action Review system boot configuration and boot media. Verify the media in C: is bootable. See
system video for additional information.
OSE1005
Message PXE boot failed.
Action Review system boot configuration, local PXE configuration, and PXE server configuration.
OSE1007
Message Diagnostic boot failed.
Action Review system boot configuration and boot media. See system video for additional
information.