Dell QHB Computer Hardware User Manual


 
Error Code Message Information
OSE1009
Message Failed to boot from CD-ROM.
Action Review system boot configuration and boot media. Verify the media in the CDROM is
bootable. See system video for additional information.
OSE1011
Message Failed to boot from ROM.
Action Check system event logs for additional exception information. Power down the system and
attempt to boot again.
OSE1013
Message Failed to boot.
Action Review system boot configuration and boot media. See system video for additional
information.
PCI1302
Message A bus time-out was detected on a component at bus <
bus
>device<
device
>function <
func
>.
Details System performance may be degraded. The device has failed to respond to a transaction.
Action Cycle input power, update component drivers, if device is removable, reinstall the device.
PCI1304
Message An I/O channel check error was detected.
LCD Message I/O channel check error detected. Power cycle system.
Action Cycle input power, update component drivers, if device is removable, reinstall the
device.
PCI1306
Message A software error was detected on a component at bus <
bus
>device<
device
>function
<
func
>.
Action Reboot the system and update the component drivers.
PCI1308
Message A PCI parity error was detected on a component at bus <
bus
>device<
device
>function
<
func
>.
LCD Message PCI parity error on bus <
bus
> device <
device
> function <
func
>. Power cycle system.
Details System performance may be degraded, PCI device may fail to operate, or system may
fail to operate.
Action Cycle input power, update component drivers, if device is removable, reinstall the
device.
PCI1310
Message A PCI system error was detected on a component at bus <
bus
>device<
device
>function
<
func
>.
LCD Message PCI system error on bus <
bus
> device <
device
> function <
func
>. Power cycle system.
Details System performance may be degraded, or system may fail to operate.
86