Dell QHB Computer Hardware User Manual


 
Error Code Message Information
PCI3006
Message Failed to get Link Tuning or FlexAddress data from iDRAC.
Details Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress.
Action Update BIOS, and BMC/iDRAC firmware. If the issue persists, see Getting Help.
PCI3008
Message A non-fatal PCIe error detected on a component at bus <
bus
>device<
device
>function
<
func
>.
Details System performance may be degraded.
Action Cycle input power, update component drivers, remove and reinstall the device at the next
service window.
PCI3010
Message A non-fatal IO error detected on a component at bus <
bus
>device<
device
>function <
func
>.
Details System performance may be degraded.
Action Cycle input power, update component drivers, remove and reinstall the device at the next
service window.
PCI3012
Message The QuickPath Interconnect (QPI) width degraded.
Details System performance may be degraded. The bus is not operating at maximum speed or
width.
Action Reset the system, if the problem persists reinstall processors.
PCI3014
Message A non-fatal PCIe error detected on a component at slot <
number
>.
Details System performance may be degraded.
Action Cycle input power, update component drivers, remove and reinstall the device at the next
scheduled service time.
PDR0001
Message Fault detected on drive <
number
>.
LCD Message Fault detected on drive <
number
>. Check drive.
Details The controller detected a failure on the disk and has taken the disk offline.
Action Remove and re-seat the failed disk. If the issue persists, see Getting Help.
PDR0002
Message A predictive failure detected on drive <
number
>.
Details The controller received a SMART error from the drive. The drive is operational but needs
replacement.
Action The drive will need replacement at the next service window.
PDR0016
Message Drive <
number
> is removed.
LCD Message Drive <
number
> is removed. Check drive.