Dialogic TX4000 PCI SS7 Network Card User Manual


 
Installing the TX 4000 board TX 4000 PCI SS7 Network Interface Board Installation Manual
The following illustration shows the H.100 termination DIP switch:
S2
OFFON
12345678
Configuring SS7 Monitor mode
DIP switch S3 controls the SS7 Monitor mode. The DIP switch is located on the front
of the board, to the right of the T1/E1 trunk connectors. By default, all S3 switches
are set to the ON position. This setting disables SS7 Monitor mode. When SS7
Monitor mode is disabled, the TX board is an active participant in the network.
To enable SS7 Monitor mode, set the S3 switches to the OFF position. In this mode,
the board becomes a passive listening device that monitors network traffic. For
information on connecting the monitoring server (with an installed TX board) to the
network and installing the SS7 Monitor software, refer to the Dialogic®
NaturalAccess™ SS7 Monitor Developer's Reference Manual and to the Installing
Dialogic® NaturalAccess™ SS7 Monitor Software instructions.
Note: The switches in DIP switch S3 must be set to either all ON or all OFF.
The following illustration shows the Monitor mode DIP switch:
S3
OFFON
1234
18 Dialogic Corporation