Eiki LC-NB3E Projector User Manual


 
Group:0 TB1274
0 TINT 32 0 ~ 63
1 SHP_EQ 2 0 ~ 3
2 SHP_FO 1 0 ~ 3
NTSC,PAL SECAM,NT4.43 S-Video Y,Cb,Cr
3 SHP_GAIN 8 8 9 9 0 ~ 15
NTSC NT4.43 PAL SECAM
4 Y_OUT_LEVEL 30 30 31 31 0 ~ 63
S-Video NTSC S-Video PAL S-Video SECAM Y,Cb,Cr
30 31 31 31
NTSC NT4.43 PAL SECAM
5 C_OUT_LEVEL 32 32 32 32 0 ~ 63
S-Video NTSC S-Video PAL S-Video SECAM Y,Cb,Cr
32 32 32 32
NTSC PAL SECAM NT4.43 PAL 60
6 Y_DELAY 6 6 3 4 4 0 ~ 15
S-Video NTSC S-Video PAL S-Video SECAM S-Video NT4.43 S-Video PAL60
443 34
7 COL_SYS - -
8XTAL - -
9 NOISE_DET - -
10 V_FREQ - - Read only
11 Vert. Std - -
12 CID - -
13 V_SIG - -
NTSC,PAL SECAM,NT4.43 S-Video YCbCr
14 Cinema SHP_GAIN 7 7 8 8 0 ~ 15 For cinema mode
Group:1 CXA2101
0 PICTURE 30 0 ~ 63
1 BRIGHT 31 0 ~ 63
2 R_DRIVE 31 0 ~ 63
3 G_DRIVE 31 0 ~ 63
4 B_DRIVE 31 0 ~ 63
5 HSEP_SEL 1 0 ~ 1
6 CR_OFFSET1 15kHz:7 Others:10 0 ~ 15
7 CB_OFFSET1 15kHz:7 Others:10 0 ~ 15
8 BLK_BOTTOM 15 0 ~ 15
NTSC PAL, SECAM 1035i Y,Cb,Cr *1 *1 Y, Cb, Cr and Y, Pb, Pr except 1035i
9 R-Y/R 6 13 6 6 0 ~ 15
10 R-Y/B 5 15 5 5 0 ~ 15
11 G-Y/R 8 8 8 8 0 ~ 15
12 G-Y/B 10 4 10 10 0 ~ 15
13 MAT_OUT 0 0 0 1 0 ~ 3
15kHz 480i, 575i 480p, 575p 1080i, 1035i, 720p
14 SYSTEM 0 1 2 0 ~ 3
15 V_TC 3 3 3 0 ~ 3
16 H_WIDTH 3 2 0 0 ~ 3
17 HS_MASK 0 1 1 0 ~ 1
Video, S-Video 480i, 575i 480p, 575p 1080i, 1035i, 720p
18 CTI_LEVEL 2 2 2 2 0 ~ 3
15kHz 480i, 575i 480p, 575p 1080i, 1035i, 720p
19 SUB_SHP 2 2 2 0 ~ 3
20 SHP_FO 0 2 3 0 ~ 3
21 PRE_OVER 2 2 3 0 ~ 3
22 LTI_LEVEL 0 1 1 0 ~ 3
23 D_PIC 0 0 0 0 ~ 3
24 HUE 31 0 ~ 63 Only adjustable for PAL,SECAM
NTSC PAL,SECAM 525i,480p 625i,575p 1035i Others
25 SUB_COL 5 5 12 12 6 9 0 ~ 15
26 SUB_HUE 7 7 8 7 9 6 0 ~ 15
27 Cinema CTI_LEVEL 2 0 ~ 3 Set this value at Cinema Mode
-30-
Electrical Adjustments
Service Adjustment Data Table
These initial values are the reference data written from the CPU
ROM to memory IC when replaced new memory IC. The adjust-
ment items indicated with “ are required to readjust following
to the “Electrical adjustments”. Other items should be used with
the initial data value.
No. Adjustment Item Initial Value Range Description