Specifications
5.3 Power Requirements
The AMC-S402 shall consume no more than the following from the system supplies
under normal operating conditions.
Table 9 Power Requirements
Part number AMC-S402xxx
Management Power
(MP)
100mA
+12V (spin up < 100
sec
)
1.5A (18W)
+12v normal operating 0.9A (10.8W)
+12v (idle) 0.5A (6W)
OFF STATE LESS THAN 0.4W
5.4 EMC Compliance
This product was tested in an EMC-compliant chassis and meets the requirements
for EN55022 Class A equipment. Compliance was achieved under the following
conditions:
Conductive chassis rails connected to earth ground, providing the path for
connecting shields to earth ground
Front panel screws properly tightened
For minimum RF emissions, it is essential that the conditions above be
implemented. Failure to do so could compromise the EMC compliance of the
equipment containing the module.
6806800H60A AMC-S402 Installation and Use 17