Emerson AXP1406 Power Supply User Manual


 
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records Power Entry Module Sensor Overview
126
2.5.4 Power Entry Module Sensor Overview
The following table lists all IPMI sensors available on the Power Entry Module.
2.5.5 Power Entry Module Analog Sensors
The analog sensors available on the PEM can be divided into the following four categories:
z Voltage Sensors
z Current Sensor
z Temperature Sensor
Table 2-134 IPMI Sensors on the PEM
Sensor
No. Sensor Name
Type of
Measurement
What does it
measure?
Sensor
Type Availability
0 Hot Swap Status State of FRU Discrete Always
1 IPMB Physical Status State of IPMB link Discrete Always
2 +3.3 V Voltage Analog Always
3 +8 V Backup Out Voltage Analog Always
4 +12 V Backplane Voltage Analog Always
5 CB 1 Status Circuit Breaker fuse
state
OEM-
reserved
Always
6 CB 2 Status Circuit Breaker fuse
state
OEM-
reserved
Always
7 CB 3 Status Circuit Breaker fuse
state
OEM-
reserved
Always
8 CB 4 Status Circuit Breaker fuse
state
OEM-
reserved
Always
9 CB 5 Status Circuit Breaker fuse
state
OEM-
reserved
Always
10 DS75 Temp Temperature Analog Always
11 +48.0 V FEED Voltage Analog Always
12 +7.5 V PEM Voltage Analog Always
13 +8 V PEM Feed 2 Voltage Analog Always
14 +12 V Current Current Analog Always
15 +8 V PEM Feed 1 Voltage Analog Always