Emerson AXP1406 Power Supply User Manual


 
SAM Module Discrete Sensors FRU Information and Sensor Data Records
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
41
2.3.6.8 Fault Event Sensor
The following table describes the discrete fault event sensor available on the physical SAM.
2.3.6.9 POST Results Sensor
The following table describes the discrete POST results sensor available on the physical SAM.
For more information on this sensor, refer to POST Results (Emerson OEM) on page 138.
Table 2-20 Sensor No. 16 Fault Event
Feature Raw Value/Description Interpreted Value
Sensor Name Fault Event
Type of Measurement Reports that the Shelf Manager
has Rebooted.
Class Discrete
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xDC OEM-reserved
Sensor Owner LUN 0x00
Entity ID 0xF0 PICMG Shelf Management
Controller
Entity Instance 0x60
Rearm mode Auto
Event message control Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x01, 0x00
Deassertion Event Mask (bytes
17,18)
0x00, 0x00
Discrete Reading Mask (bytes
19, 20)
0x01, 0x00 Supports 1 State
Reading Definition According to Motorola XXX
Table 2-21 Sensor No. 17 POST Results
Feature Raw Value/Description Interpreted Value
Sensor Name POST Results
Type of Measurement POST Results
Class Discrete
Event/Reading Type 0x06 'digital' Discrete
Sensor Type 0x28 Management Subsystem Health
Sensor Owner LUN 0x00
Entity ID 0xF0 PICMG Shelf Management
Controller
Entity Instance 0x60