AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records Power Configuration
56
2.4.3 Power Configuration
The following table describes the power configuration for the Active SAM.
2.4.4 Active SAM1000 Sensor Overview
The following table lists the discrete and analog sensors that reside on the Active SAM. The
information in this section supports the SAM on both the AXP1406 and AXP1600 shelves. The
AXP1600 FRU and sensor data is highlighted and/or marked for ease of use.
Rows that are highlighted in blue provide information for the additional sensors on the
SAM1000 for the AXP1600.
Table 2-24 SAM1000 Active Power Configuration
Item Value Meaning
Dynamic power reconfiguration support No Possibility to change FRU power consumption
without switching it off, according to
AdvancedTCA
Dynamic power configuration No Are the power draw levels fixed or these may vary
if additional components are hot inserted or
onboard components’ power consumption is
changing dynamically
Number of power draw levels 1 The amount of possible power levels, normally 1
Early power draw levels, Watt 5 Complete early power consumption including
IPMC
Steady state power draw levels, Watt 5 Complete steady power consumption including
IPMC
Transition from Early to Steady levels,
sec
0 How long does board consumes early power.
Early power is normally bigger than steady
Table 2-25 Active SAM1000 Sensor Overview
Sensor
No. Sensor Name
Type of
Measurement
What does it
measure?
Sensor
Type Availability
0FRU 0
HOT_SWAP
Status State of FRU Discrete Always
2FRU 1
HOT_SWAP
Status State of FRU Discrete Always
3FRU 2
HOT_SWAP
Status State of FRU Discrete Always
4FRU 3
HOT_SWAP
Status State of FRU Discrete Always
5FRU 4
HOT_SWAP
Status State of FRU Discrete Always
6FRU 5
HOT_SWAP
Status State of FRU Discrete Always