Emerson AXP1406 Power Supply User Manual


 
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records SAM Module Discrete Sensors
40
2.3.6.7 +12 V A Valid Sensor
The following table describes the discrete +12V A valid sensor available on the physical SAM.
Rearm mode Auto
Event message control Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x03, 0x00
Deassertion Event Mask (bytes
17,18)
0x00, 0x00
Discrete Reading Mask (bytes
19, 20)
0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
Table 2-18 Sensor No. 14 12 V B Valid (continued)
Feature Raw Value/Description Interpreted Value
Table 2-19 Sensor No. 15 12 V A Valid
Feature Raw Value/Description Interpreted Value
Sensor Name 12 V In A Valid
Type of Measurement State of Power Unit A
Class Discrete
Event/Reading Type 0x03 'digital' Discrete
Sensor Type 0x09 Power Unit
Sensor Owner LUN 0x00
Entity ID 0xF0 PICMG Shelf Management
Controller
Entity Instance 0x60
Rearm mode Auto
Event message control Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x03, 0x00
Deassertion Event Mask (bytes
17,18)
0x00, 0x00
Discrete Reading Mask (bytes
19, 20)
0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5