Emerson AXP1406 Power Supply User Manual


 
FRU Device Commands Supported IPMI Commands
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
19
1.2.8 FRU Device Commands
The IPMC supports the following FRU device commands.
1.2.9 SDR Device Commands
The IPMC supports the following SDR device commands.
1.2.10 SEL Device Commands
The IPMC supports the following SEL device commands.
Table 1-8 Supported FRU Commands
Command NetFn Rq/Rs CMD
Active
ShelfMgr
Physical
ShelfMgr PEMs FTMs
ATCA
Blades
Get FRU Inventory Area Info 0x0A/0x0B 0x10 X X X X X
Read FRU Data 0x0A/0x0B 0x11 X X X X X
Write FRU Data 0x0A/0x0B 0x12 X X X X X
Table 1-9 Supported SDR Device Commands
Command
NetFn
Rq/Rs CMD
Active
ShelfMgr
Physical
ShelfMgr PEMs FTMs
ATCA
Blades
Get SDR Repository Info 0x0A/0x0B 0x20 X
Get SDR Repository
Allocation Info
0x0A/0x0B 0x21
Reserve SDR Repository 0x0A/0x0B 0x22 X
Get SDR 0x0A/0x0B 0x23 X
Add SDR 0x0A/0x0B 0x24 X
Partial Add SDR 0x0A/0x0B 0x25 X
Delete SDR 0x0A/0x0B 0x26 X
Clear SDR Repository 0x0A/0x0B 0x27 X
Get SDR Repository Time 0x0A/0x0B 0x28 X
Set SDR Repository Time 0x0A/0x0B 0x29 X
Table 1-10 Supported SEL Commands
Command
NetFn
Rq/Rs CMD
Active
ShelfMgr
Physical
ShelfMgr PEMs FTMs
ATCA
Blades
Get SEL Info 0x0A/0x0B 0x40 X
Get SEL Allocation Info 0x0A/0x0B 0x41 X
Reserve SEL 0x0A/0x0B 0x42 X
Get SEL Entry 0x0A/0x0B 0x43 X X