Epson C82315 Network Card User Manual


 
Command
Command
Number
Parameters Name/Description Examples
(HH..HH)
&%Z09,0(1B40)
Defines the string of hexadecimal values that are
sent to the printer as HH..HH
10
Define User Custom command-pass-thru strings
for details.
Defines up to eight strings (0-7) of commands
(up to 25 characters can be included in the
string). See User-defined command-pass-thru
strings for details.
#(HH..HH)
&%Z10,3(1B45)
Defines string number # to be the character
string defined by the hexadecimal values
HH..HH
DISPLAY STATION SETUP MODE
When the printer is connected to a twin-axial cable that is also connected to a
display station, you can display an interface setup screen showing various setup
parameters. You can then change these parameters and save them in the
interface memory.
See Appendix A-2 for an example of the setup screen.
Follow the steps below to change settings in display station setup mode.
1.
Turn off the printer and all devices connected to the same twin-axial cable.
2.
Disconnect the twin-axial cable from the IBM host computer, and make sure
that at least one display station is connected to the cable and is turned on.
3.
Turn off switch 8 to deactivate the twinax interface. Then make sure you
have set a valid address other than 7 (switches 1,2,3), and turn on the printer.
4.
Press the TEST button on the interface. The interface setup screen appears
on the display station.
5.
Use the cursor keys to move to settings you want to change. Use the
backspace to delete old settings, then type in the new settings.
14