Extron electronic DTPTEU332 Network Router User Manual


 
Command and Response Table for SIS Commands (continued)
DTP T EU 332, DTP T EU 232, DTP T MK 332, and DTP T MK 232 • Remote Control 25
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Horizontal start
Set horizontal start value
E
2*
X1%
HSRT
}
Hsrt2*
X1%]
Increment horizontal start
E
2+HSRT
}
Hsrt2*
X1%]
Decrement horizontal start
E
2–HSRT
}
Hsrt2*
X1%]
View horizontal start
E
2HSRT
} X1%]
Vertical start
Set vertical start value
E
2*
X1%
VSRT
}
Vsrt2*
X1%]
Increment vertical start
E
2+VSRT
}
Vsrt2*
X1%]
Decrement vertical start
E
2–VSRT
}
Vsrt2*
X1%]
View vertical start
E
2VSRT
} X1%]
TP function switch position
View switch position
E
O1HDBT
}
HdbtO1*
X1@]
NOTE: The “HdbtO1*“ portion of response is returned in Verbose mode 2 and 3 only.
Device Name
Set the unit name
EX1^
CN
}
Ipn
X1^]
Change the name to one of your choosing.
Set unit name to factory default
E
CN
}
Ipn
DTP
-
T
-
EU(MK
)-
332(232
)
]
View unit name
E
CN
} X1^]
Reset
Reset to factory setting
E
ZXXX
}
Zpx
]
Reset to factory defaults.
Information requests
Information request
I
In
X!
Aflw
X!
Ausw
X@
Vmt
X$
Amt
X$]
Example:
I
In1
Aflw2
Ausw1
Vmt1
Amt0
]
Input 1 is selected, analog audio is
assigned to input 2, the switcher is in
auto-input switching (high) mode, video
is muted and analog audio is unmuted.
Request part number
N
60-nnnn-nn
]
See www.extron.com, for part numbers.
Query controller firmware version
Q
X1&]
Example:
Q
1.23
]
The factory-installed controller firmware
version is 1.23 (sample value only).
Verbose mode
NOTE: If tagged responses are enabled (modes 2 and 3), all “view” commands return the prefix and the value, just as the “set”
commands do. For example, the View front panel switch mode (
E
AUSW
}
) command returns “Ausw
X@]
”.
Set verbose mode
EX1*
CV
}
Vrb
X1*]
Read verbose mode
E
CV
} X1*]
NOTE:
X!
= Input number 0
= No input
1
= HDMI input
2
=
VGA
input
X@
= Switch mode 0 = Manual 1 = Auto switch VGA (default) 2 = Auto switch HDMI
X$
= Status 0 = Not enabled 1 = Enabled
X1@
= Switch position 0 = DTP 1 = HDBT
X1%
= Horizontal and vertical start 000255 (128 = default)
X1^
= Switcher name A text string of up to 24 alphanumeric characters and minus sign/hyphen (-).
No blank or space characters are permitted as part of a name.
The first letter must be a letter, and the last character must not be a minus sign/hyphen.
X1&
= Firmware version number to second decimal place (x.xx)
X1*
= Verbose mode 0 = clear/none 2 = tagged responses for queries
1 = verbose mode (default) 3 = verbose mode and tagged for queries