The response should be the new IP address of the PCS4, as shown below.
Figure 10. Screen Showing the Ping Command
You can reconnect using either Telnet or a web browser to verify that the update was
successful.
6. After verifying that the IP address change was successful, issue the arp -d command at
the DOS prompt to remove the address from the ARP table. For example:
arp -d 10.13.170.15
A space must separate arp from the hyphen (-).
Setting Up the Computer Using a Web Browser
To set up the PCS4 using a web browser, you must temporarily configure the computer to
communicate with the interface. Then you can change the PCS4 default settings (IP address,
subnet mask, and [optionally] administrator name and password) in order to use the unit
on an intranet (LAN) or on the Internet (WAN). After you have set up the PCS4 for network
communication, you can reset the computer to its original network configuration.
IPL T PCS4 LAN port defaults:
PCS4 IP address: 192.168.254.254
Gateway IP address: 0.0.0.0
Subnet mask: 255.255.0.0
DHCP: Off
Link speed and duplex level: Auto detected
If you use an existing Ethernet LAN intranet, your network administrator can provide you
with a unique IP address for the PCS4 or confirm whether you need to set up the PCS4 for
Dynamic Host Conguration Protocol (DHCP) to have an address assigned automatically
when you sign on.
IPL T PCS4 • HTML Configuration and Control 17