Extron electronic IPL T PCS4 Network Hardware User Manual


 
Reference
Material
This section contains reference information on the IPL T PCS4 and IPL T PCS4i. The following
topics are covered:
Specifications
Part Numbers and Accessories
Mounting the IPL T PCS4 Interface
Specifications
Ethernet control interface
Connectors .................................... 1 female RJ-45 female connector
Data rate ........................................ 10/100Base-T, half/full duplex with autodetect
Protocols ........................................ ARP, ICMP (ping), IP, TCP, UDP, DHCP, HTTP, SMTP, Telnet
Default settings .............................. Link speed and duplex level = autodetected
IP address = 192.168.254.254
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off
Web server ..................................... Up to 200 simultaneous sessions
960 kB nonvolatile user memory
Program control ............................. Extron Simple Instruction Set
(SIS)
Global Viewer requirements ........... Microsoft Internet Explorer ver. 6 or higher
AC control interface
Connectors
IPL T PCS4 ............................... 4 USA/Edison power connectors
IPL T PCS4i ............................... 4 IEC power connectors
Voltage
IPL T PCS4 ............................... 120 VAC, 50-60 Hz
IPL T PCS4i ............................... 220 VAC, 50-60 Hz
Minimum AC load
IPL T PCS4 ............................... 20 mA, 2.4 watts at 120 VAC
IPL T PCS4i ............................... 20 mA, 4.4 watts at 220 VAC
Maximum AC load, aggregate
IPL T PCS4 ............................... 10 A, 1200 watts at 120 VAC
IPL T PCS4i ............................... 10 A, 2200 watts at 220 VAC
Maximum AC load, individual
IPL T PCS4 ............................... 10 A, 1200 watts at 120 VAC
IPL T PCS4i ............................... 10 A, 2200 watts at 220 VAC
54 IPL T PCS4 • Reference Material