Fluke Ti45 Power Supply User Manual


 
Appendices
Camera Specifications and Dimensions D
D-3
Table D-1. Camera Specifications, Ti45 and Ti40 Models (cont.)
Model Name
Ti45 Model
with
IR Fusion
Ti45 Model
without
IR Fusion
Ti40 Model
with
IR Fusion
Ti40 Model
without
IR Fusion
Temperature Measurement
Calibrated
Temp.
Ranges
Range 1 = -20 °C to 100 °C
(-4˚F to 212˚F)
Range 2 = -20 °C to 350 °C
(-4 °F to 662 °F)
Range 3 = 250 °C to 600 °C
(482˚F to 1112˚F)
Range 4 = 500 °C to 1200 ˚C
(932 °F to 2192 °F) (option)
Range 1 = -20 °C to 100 °C
(-4˚F to 212˚F)
Range 2 = -20 °C to 350 °C
(-4 °F to 662 °F)
Accuracy ±2 °C or ± 2 %
Measurement
Modes
Movable points & boxes
Centerpoint
Cursor temp.
Center box (area min/max,
average)
Automatic hot and cold
point detection
Isotherm (only on models
without IR Fusion)
Color alarm (only on models
with IR Fusion)
Center-point
Cursor temp.
Center box (area min/max,
average)
Emissivity
Correction
Based on user input. Variable from 0.01 to 1.0 (0.01
increments)
Power
Battery Type Li-Ion Smart Battery, rechargeable, field-replaceable
Battery
Operating
Time
3 hours continuous operation