Fujitsu M4000/M5000 Server User Manual


 
B-2 SPARC Enterprise M4000/M5000 Servers Installation Guide December 2010
Refer to the SPARC Enterprise M4000/M5000 Servers Service Manual for LED status.
B.2 Using the Diagnostic Commands
The following commands are detailed in this section.
Section B.2.1, “Using the showhardconf Command” on page B-2
Section B.2.2, “Using the showlogs Command” on page B-5
Section B.2.3, “Using the showstatus Command” on page B-6
Section B.2.4, “Using the fmdump Command” on page B-6
Section B.2.5, “Using the fmadm faulty Command” on page B-7
Section B.2.6, “Using the fmstat Command” on page B-8
B.2.1 Using the showhardconf Command
The showhardconf command displays information about each FRU. The following
information is displayed:
Current configuration and status
Number of installed FRUs
Domain information
IOBOX information
Name properties of PCI cards
TABLE B-2 Types of Troubleshooting Methods
Troubleshooting Method Description
Check LEDs The system LEDs (on the operator panel) indicate any system or
hardware error detected during initial diagnosis or system
operation. Additional LEDs are provided on the XSCF Unit, power
supply unit, fan unit, and other units so that you can always locate
faulty components and identify specific errors.
Check log files System messages are often displayed on the system console. These
messages can alert you to system problems, such as a device that is
about to fail.
Check using the XSCF
Shell
You can use the XSCF Shell to find details of an error state, the
device status history, and other status information.