Fujitsu M9000 Server User Manual


 
Chapter 4 FRU Replacement Preparation 4-7
The command is menu-driven. The example continues using a FAN unit.
The replacefru command will automatically test the status of the component after the
disconnecting off and replace has finished.
Select [1-5|c:cancel] :2
---------------------------------------------------
Maintenance/Replacement Menu
Please select a FAN to be replaced.
No. FRU Status
--- --------------- ------------------
1. FAN_A#0 Normal
2. FAN_A#1 Normal
3. FAN_A#2 Normal
4. FAN_A#3 Normal
5. FAN_B#0 Normal
6. FAN_B#1 Normal
7. FAN_B#2 Normal
8. FAN_B#3 Normal
9. FAN_B#4 Normal
10. FAN_B#5 Normal
11. FAN_B#6 Not installed
12. FAN_B#7 Not installed
---------------------------------------------------
Select [1-12|b:back] :1
You are about to replace FAN_A#0.
Do you want to continue?[r:replace|c:cancel] :r
Please confirm the Check LED is blinking.
If this is the case, please replace FAN_A#0.
After replacement has been completed, please select[f:finish] :f