Chapter 1 Safety and Tools 1-9
1.4 Antistatic Precautions
During normal operations, all components mounted in the server, including the dummy
(filler) units, are properly grounded through the chassis.
Prior to performing maintenance, ensure that any static electricity is discharged from the
FRUs to be inserted and the person performing the maintenance. Both must be properly
grounded.
Ensure that the procedures below are followed for proper grounding.
1.4.1 Removing Static Electricity
This section explains the procedures for removing static electricity.
1. Connect the earth conductor of the antistatic mat to the server grounding port. (See
FIGURE 1-7 to FIGURE 1-10)
Note – Do not use antistatic bags or packaging materials in place of a grounded antistatic
mat when handling the FRUs.
FIGURE 1-1 Antistatic Mat
2. Connect an antistatic wrist strap clip to a server grounding port. (See FIGURE 1-7 to
FIGURE 1-10)