25-6 SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
5. Switch on all main line switches for the AC section (ACS) in the power supply
system.
6. Confirm that the XSCF STANDBY LED (green) on the operator panel remains lit.
If it is blinking, wait until it remains lit.
7. Use one of the following methods to start (power on) all domains at once.
■ Press and hold down (for less than four seconds) the POWER switch on the operator
panel.
■ From a console that is connected to XSCF, execute the poweron -a command of
XSCF.
8. Confirm configuration information of the system by using the showhardconf
command of XSCF.
If the deleted FRU is not displayed, it is operating normally.
9. When CMUs or IOUs are deleted, cancel the SB settings and domain settings for
each CMU and IOU.
Ask a system administrator or a domain administrator for assistance.
10. Set the mode switch on the operator panel to Locked.
XSCF> showhardconf