1. From the Oracle Solaris OS use the cfgadm command to get the component status:
AP_ID is comprised of the IOU number (iou#0 or iou#1) and the PCI cassette slot number
(pci#1, pci#2, pci#3, pci#4)
2. Use the cfgadm command to unconfigure the component from the hardware:
where AP_ID is the IOU and PCI card as shown in the output of cfgadm.
3. Use the cfgadm command to stop supplying power to the component:
where AP_ID is the IOU and PCI card as shown in the output of cfgadm.
4. Use the cfgadm command to confirm the component from the domain is now
disconnected and unconfigured:
# cfgadm
AP_ID Type Receptacle Occupant Condition
...
iou#0-pci#1 unknown empty unconfigured unknown
iou#0-pci#2 unknown empty unconfigured unknown
iou#0-pci#3 etherne/hp connected configured ok
iou#0-pci#4 fibre/hp connected configured ok
# cfgadm -c unconfigure AP_ID
# cfgadm -c disconnect AP_ID
# cfgadm
AP_ID Type Receptacle Occupant Condition
...
iou#0-pci#1 unknown empty unconfigured unknown
iou#0-pci#2 unknown empty unconfigured unknown
iou#0-pci#3 etherne/hp disconnected unconfigured ok