Fujitsu M9000 Server User Manual


 
4-4 SPARC Enterprise M8000/M9000 Servers Service Manual October 2012
4.2.1 Disconnecting a FRU from a Domain
4.2.1.1 Disconnecting a CMU/IOU
Perform the following procedure to disconnect a CMU or IOU when the Oracle Solaris OS is
operating:
1. Checking resources
Check the resources that are connected to a CMU or IOU to be disconnected, and verify
that the system is not affected when it is disconnected.
2. Disconnecting from the domain
To disconnect the CMU or IOU from the domain, enter the following command from the
terminal that is connected to the XSCF:
The system administrator permission is required for executing this command.
4.2.1.2 Disconnecting a PCI card
Caution – Before you remove the PCI cassette, make sure that there is no activity on the
card in the cassette.
Caution – In the PCI cassette part, when removing cables such as LAN cable, if your
finger can't reach the latch lock of the connector, press the latch with a flathead screwdriver
to remove the cable. Forcing your finger into the clearance can cause damage to the PCI
card.
XSCF> deleteboard 01-0