Fujitsu M9000 Server User Manual


 
Chapter 25 Addition, Deletion, and Upgrade of FRU 25-9
6. After the XCP update is completed, reboot the XSCF via the rebootxscf
command.
7. After the XSCF reset, log in to XSCF again.
8. By using XSCF, mount the add-on component and install it into the server.
a. Execute the addfru(8) command and select "CMU/IOU" from the maintenance
menu.
b. Based on Section 6.2, “Active Replacement and Hot Replacement” on page 6-5 or
Section 7.2, “Active Replacement and Hot Replacement” on page 7-8, perform the
add-on operation according to the instructions displayed in the maintenance
menu.
For details on how to mount CPU module (CPUM) to CMU, see Section 6.4.2, “CPU
Module Replacement” on page 6-25.
Caution – To the add-on component, do not fail to execute the diagnostic test which is
provided in the maintenance menu of the addfru(8) command.
9. Confirm that the mounted component has been recognized by the server, and the
error indicator asterisk (*) is not displayed.
10. Use the showlogs error -v command and the showstatus(8) command, to
confirm that no errors occurred.
11. Change the mode switch setting on the operator panel from Service to Locked, to put
it back.
12. Configure the following settings for the add-on component.
XSB settings
Domain configuration
Settings of the CPU operational mode of the domain
For each setting, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User’s Guide.
XSCF> rebootxscf
XSCF> addfru
XSCF> showhardconf -M
XSCF> showlogs error -v
XSCF> showstatus