Fujitsu M9000 Server User Manual


 
Chapter 6 Replacement of CPU/Memory Board Unit (CMU), CPU Module, and DIMM 6-21
20. Use one of the following methods to start (power on) all domains at once.
Press and hold down (for less than four seconds) the POWER switch on the operator
panel.
From the console that is connected to XSCF, execute the poweron -d <domain-id>
command of XSCF for the domain of the swap target new CMU.
Power to all the domains is turned on. Firmware version synchronization of the target
domain is automatically performed.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On” on
page 4-22, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
User’s Guide.
21. Using the XSCF version command, confirm that the firmware version of the target
domain is the same in the replacement CMU.
For details of firmware version synchronization, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide.
22. Confirm that the replacement components are normal by using the showhardconf
or showstatus command of XSCF.
Unless "*" is displayed for a replacement CMU, CPU module, or DIMM, it is operating
normally.
For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide, the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
Note – The showstatus command displays information on degraded components.
23. Restore the original mode switch setting on the operator panel.
Note – When the maintenance work is completed, be sure to confirm the mode switch
setting and return the switch to Locked.
24. Close the door on the server, and lock it.