Fujitsu M9000 Server User Manual


 
Chapter 25 Addition, Deletion, and Upgrade of FRU 25-13
If you found any errors on the hardware, contact a certified service engineer.
18. Change the mode switch setting on the operator panel from Service to Locked, to put
it back.
19. Set up and confirm the CPU operational mode of the domain.
For details, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User’s Guide. In the document, see the chapter of "Setting Up XSCF."
20. Power on the target domain.
21. Confirm that the target domain has been properly started.
22. Use the showlogs error -v command and the showstatus(8) command, to
confirm that no errors occurred.
If you found any errors on the hardware, contact a certified service engineer.
25.3.4 CMU/IOU Replacement as an Upgrade in an Existing
Domain
1. Update the Oracle Solaris OS to the version of minimum requirements which is
described in the Product Notes of the appropriate XCP version, or apply the
mandatory patches.
2. Prior to replacing with new CMU/IOU, apply the appropriate patches to the
software in use, if it is necessary.
3. Log in to XSCF using an account with the platadm and fieldeng administrative
privileges.
XSCF> showlogs error -v
XSCF> showstatus
XSCF> poweron -d domain_id
XSCF> showlogs power
XSCF> showlogs error -v
XSCF> showstatus