Chapter 25 Addition, Deletion, and Upgrade of FRU 25-5
25.2.1 Active Deletion
First, select a unit to be deleted as described below.
1. Log in to the XSCF.
2. Execute the deletion command (deletefru).
3. When the following deletion menu is displayed, select the type of FRU to be deleted.
FIGURE 25-2 Initial Page of the Maintenance Menu
Note – The display may vary depending on the XCP version.
Perform the operation according to the instructions displayed in the deletion menu. For
details, see the appropriate chapter on FRU replacement.
25.2.2 Cold Deletion
In cold deletion the main line switches of the system are turned off and the deletion menu is
not available. Perform the deletion according to the following steps.
1. Set the mode switch on the operator panel to Service.
2. Use one of the following methods to stop (power off) all domains at once.
■ Press and hold the POWER switch on the operator panel for at least four seconds.
■ From a console that is connected to XSCF, log in to XSCF, and execute the
poweroff -a command.
3. Switch off all main line switches for the AC section (ACS) in the power supply
system.
4. Delete the FRUs.
Perform the same operation as the removal steps of a FRU replacement. For details, see
the appropriate chapter on FRU replacement.
XSCF> deletefru
---------------------------------------------------
Maintenance/Removal (Deletion) Menu
Please select a type of FRU to be removed (deleted).
1. CMU/IOU (CPU Memory Board Unit/IO Unit)
---------------------------------------------------
Select [1|c:cancel]: