Fujitsu M9000 Server User Manual


 
4-8 SPARC Enterprise M8000/M9000 Servers Service Manual October 2012
When the tests are complete the program will return to the original menu. Select cancel to
return to the XSCF Shell prompt.
Note – The display may vary depending on the XCP version.
4.2.3 Configuring a FRU into a Domain
4.2.3.1 Configuring CMU/IOU
Perform the following procedure to configure a CMU or IOU when the Oracle Solaris OS is
operating:
Diagnostic tests for FAN_A#0 have started.
[This operation may take up to 2 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90.....done
--------------------------------------------------
Maintenance/Replacement Menu
Status of the replaced unit.
FRU Status
------------- --------
FAN_A#0 Normal
--------------------------------------------------
The replacement of FAN_A#0 has completed, normally.[f:finish] :f
--------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. CMU/IOU (CPU Memory Board Unit/IO Unit)
2. FAN (Fan Unit)
3. PSU (Power Supply Unit)
4. XSCFU (Extended System Control Facility Unit)
5. DDC_A (DDC for BP_A)
--------------------------------------------------
Select [1-5|c:cancel] : C
XSCF>