23-8 SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
FIGURE 23-5 Removing the SWBP (Front of the M9000)
10. Place the removed SWBP on an antistatic mat.
11. Mount the replacement SWBP by following the removal instructions in Step 8 and
Step 9 in reverse order.
Caution – Do not forcibly push the SWBP when inserting it, even if it is not moving
smoothly. You may fail to insert the SWBP due to the presence of any obstruction in a slot or
any problem with a connector pin; and if you forcibly insert it, serious damage may result.
Caution – The connector on the left edge of the base plate of the switch BP is not used for
the M8000 server. Be aware of this when connecting cables.
12. Switch on all main line switches for the AC section (ACS) in the power supply
system.
13. Confirm that the XSCF STANDBY LED (green) on the operator panel remains lit.
If it is blinking, wait until it remains lit.