Fujitsu M9000 Server User Manual


 
4-20 SPARC Enterprise M8000/M9000 Servers Service Manual October 2012
Output for the showhardconf command (Continued)
Refer to the showhardconf man page for more information.
2. Verify the indicator LEDs on the FRU.
Refer to
TABLE 2-11 and TABLE 2-12 for LED status.
Note – For notes to observe when executing the addfru, deletefru or replacefru
command, see Section 4.2.4, “Confirming the Hardware” on page 4-9.
4.4 Cold Replacement
In cold replacement all business operations are stopped. Cold replacement is the act of
powering off the server and disconnecting input power. This is normally required for safety
when the inside of the server is accessed. The work of cold replacement consists of the
following three steps:
Section 4.4.1, “Powering the Server Off” on page 4-21
Section 4.4.2, “Powering the Server On” on page 4-22
PSU#0 Status:Normal; Serial:FA11155187;
+ FRU-Part-Number:CA01022-0690 20H /371-2219-08 ;
+ Power_Status:On;
:
FANBP_A#0 Status:Normal; Ver:0101h; Serial:PP0607D266 ;
+ FRU-Part-Number:CA21128-B71X 011AE/371-2222-05 ;
FAN_A#0 Status:Normal; Serial:PA0605B287;
+ FRU-Part-Number:CA06622-D012 A5 /371-2237-01 ;
:
FAN_A#15 Status:Normal; Serial:PA0605B303;
+ FRU-Part-Number:CA06622-D012 A5 /371-2237-01 ;
:
FANBP_B#0 Status:Normal; Ver:0201h; Serial:PP0607D270 ;
+ FRU-Part-Number:CA21128-B72X 011AE/371-2223-05 ;
FAN_A#4 Status:Normal; Serial:PA0605B297;
+ FRU-Part-Number:CA06622-D012 A5 /371-2237-01 ;
:
FAN_A#9 Status:Normal; Serial:PA0605B300;
+ FRU-Part-Number:CA06622-D012 A5 /371-2237-01 ;
:
SWBP#0 Status:Normal; Ver:0101h; Serial:PP0607E759 ;
+ FRU-Part-Number:CA20397-B57X 022AG/371-2243-01 ;
MEDBP#0 Status:Normal; Ver:0101h; Serial:PP06058497 ;
+ FRU-Part-Number:CA20397-B56X 005AA/371-2244-01 ;