Chapter 13 PCI Slot Device Replacement 13-21
b. If the lever stops halfway even when the PCI cassette is inserted again, pull the
PCI cassette out from the IOU, and then check whether the PCI card is set in the
normal position. Then, reinsert the PCI cassette.
Caution – Do not forcibly push the lever of the PCI cassette when the lever is pushed but
stops halfway. In this case, restore the lever to its original position, and then reinsert it. If the
lever stops halfway even when the PCI cassette is inserted again, it is possible that the PCI
card is not set in the normal position (see a, b and c of Step 8). Pull the PCI cassette out from
the IOU, check the position of the PCI card, and then reinsert it.
10. Turn on power to the relevant domain.
From a console that is connected to XSCF, execute the poweron -d command of XSCF.
The power to all the domains is turned on, and then the power-on self test (POST) is
executed. When ok prompt displayed on the console of relevant domain, POST is
completed.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On” on
page 4-22, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
User’s Guide.
11. Close the door on the server, and lock it.
13.4 Cold Replacement
In cold replacement, none of the replacement work is performed with the maintenance menu
from a terminal connected to XSCF.
The procedure is as follows.
1. Unlock and open a door of the server. (See Chapter 5)
Caution – Before touching a FRU or dummy (filler) unit, see Section 1.4, “Antistatic
Precautions” on page 1-9 and be sure to wear the antistatic wrist strap. Failure to do so might
result in serious damage to operating domains.