Fujitsu M9000 Server User Manual


 
Chapter 11 XSCF Unit Replacement 11-5
11.2 Active Replacement and Hot Replacement
Note – To replace the XSCF Unit, you must consider the version of the XCP that is
currently in the server.
To determine the firmware version of the server, type:
For more information, refer to the version (8) man page or the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual.
If the version of XCP in your server is XCP 1041 or earlier, see Appendix E. If the server has
XCP1050 or later, follow the procedure described below.
The active replacement procedure and hot replacement procedure for the XSCFU are the
same.
The procedure is as follows.
1. Unlock and open a door of the server. (See Chapter 5)
Caution – Before touching a FRU or dummy (filler) unit, see Section 1.4, “Antistatic
Precautions” on page 1-9 and be sure to wear the antistatic wrist strap. Failure to do so might
result in serious damage to operating domains.
2. When the Active LED (green) of the XSCFU to be replaced is lit, log in to the XSCF
from a terminal connected to the XSCF, and then execute the switchscf command
for switching to Standby.
XSCF> version -c xcp
XSCF> switchscf -t Standby