Fujitsu M9000 Server User Manual


 
Chapter 11 XSCF Unit Replacement 11-11
For details of the unlockmaintenance command, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide, the SPARC
Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
ii. Execute the showhardconf command.
And, confirm that the currently active XSCF unit is the one, which you are
going to replace with using replacefru command.
iii. After confirming that the system did not switch the other XSCF unit as
active, re-execute the replacefru command.
(a)When you can execute the replacefru command
Follow the replacefru command to replace the unit.
(b)In case communication with XSCF is lost after you physically replaced
the target XSCF
The new XSCF unit is physically mounted; however, the mounting process
is not yet finished completely. When the replacefru command showed a
message which prompts the replacement of XSCF unit, once extract the
inserted XSCF unit which has undergone the replacement, and then reinsert
it.
Note – If an attempt to re-execute the replacefru command from the active
XSCF fails, or if an XSCF failover occurred and the XSCF units switched, both XSCF
units will require cold replacement. For information on cold replacement, see
Section 11.3, “Cold Replacement” on page 11-12.
11. Confirm that the replacement components are normal by using the
showhardconf or showstatus command of XSCF.
Unless "*" is displayed for the replacement XSCFU, it is operating normally.
For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide,
the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
Note – The showstatus command displays information on degraded components.
12. Confirm that the version of the replaced XSCF unit is the same. If the version
number is different, upgrade the firmware again to match up the version
numbers.
XSCF> unlockmaintenance