Fujitsu M9000 Server User Manual


 
Chapter 4 FRU Removal Preparation 4-11
Output for the showhardconf command (Continued)
2. Verify the status LEDs on the PCI cassette.
The POWER LED should be lit and the CHECK LED should not be lit.
Note – If an XSCF failover occurs while executing the addfru, deletefru or
replacefru command, the addition, removal or replacement of FRUs may not have
been completed successfully. In such case, log in again to the active XSCF to confirm
that the addition, removal or replacement of FRUs was successfully completed. If the
addition, removal or replacement of the FRUs was not completed successfully,
re-execute the following commands in the manner described:
- For addfru command execution, execute the deletefru command for the
relevant FRU, and then re-execute the addfru command.
- For deletefru command execution, re-execute the deletefru command for the
relevant FRU.
- For replacefru command execution, re-execute the replacefru command for
the relevant FRU.
OPNL#0 Status:Normal; Ver:0101h; Serial:PP06058246 ;
+ FRU-Part-Number:CA06629-D061 A1 ;
PSU#0 Status:Normal; Serial:;
+ FRU-Part-Number:CA01022-0690;
+ Power_Status:On;
:
FANBP_A#0 Status:Normal; Ver:0101h; Serial:PP0607D266 ;
+ FRU-Part-Number:CA21123-B54X 003AC ;
FAN_A#0 Status:Normal; Serial:PA0605B287;
+ FRU-Part-Number:CA06501-D023 A2 /371-2222-00 ;
:
FAN_A#15 Status:Normal; Serial:PA0605B303;
+ FRU-Part-Number:CA06501-D023 A2 /371-2222-00 ;
:
FANBP_B#0 Status:Normal; Ver:0201h; Serial:PP0607D270 ;
+ FRU-Part-Number:CA21123-B55X 003AC ;
FAN_A#4 Status:Normal; Serial:PA0605B297;
+ FRU-Part-Number:CA06501-D023 A2 /371-2222-00 ;
:
FAN_A#9 Status:Normal; Serial:PA0605B300;
+ FRU-Part-Number:CA06501-D023 A2 /371-2222-00 ;
:
SWBP#0 Status:Normal; Ver:0101h; Serial:PP0607E759 ;
+ FRU-Part-Number:CA20394-B16X 001AA ;
MEDBP#0 Status:Normal; Ver:0101h; Serial:PP06058497 ;
+ FRU-Part-Number:CA20394-B17X 002AB ;