Fujitsu M9000 Server User Manual


 
Chapter 2 Product Overview and Troubleshooting 2-19
CHECK Amber Indicates the operating status of the SPARC Enterprise server.
Off Normal state. Otherwise, this indicates that the main
line switches were switched off or a power failure
occurred.
Blinking
(*1)
Indicates that the operator panel is the maintenance
target device.
Lit Indicates that the server cannot be started.
Note – *1)If the maintenance target component is indicted by a blinking CHECK
LED, the LED may be called a locater.
TABLE 2-2 State Display by LED Combination (Operator Panel)
LED
Description of the state
POWER XSCF
STANDBY
CHECK
Off Off Off The main line switch is switched off.
Off Off On The main line switch is switched on.
Off Blinking Off The XSCF is being initialized.
Off Blinking On An error occurred in the XSCF.
Off On Off The XSCF is on standby.
The system is waiting for power-on of the air conditioning
system.
On On Off Warm-up standby processing is in progress (power-on is
delayed).
The power-on sequence is in progress.
The system is in operation.
Blinking On Off The power-off sequence is in progress.
Fan termination is being delayed.
TABLE 2-1 State Display by the LEDs (Operator Panel) (Continued)
LED Name Light color Description of function and state