Fujitsu M9000 Server User Manual


 
4-14 SPARC Enterprise M8000/M9000 Servers Service Manual June 2010
When the tests are complete the program will return to the original menu. Select
cancel to return to the XSCF Shell prompt.
Note – The display may vary depending on the XCP version.
Diagnostic tests for FAN_A#0 have started.
[This operation may take up to 2 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90.....done
---------------------------------------------------
Maintenance/Replacement Menu
Status of the replaced unit.
FRU Status
------------- --------
FAN_A#0 Normal
---------------------------------------------------
The replacement of FAN_A#0 has completed, normally.[f:finish] :f
---------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. FAN (Fan Unit)
2. PSU (Power Supply Unit)
---------------------------------------------------
Select [1,2|c:cancel] : C
XSCF>