Fujitsu M9000 Server User Manual


 
6-28 SPARC Enterprise M8000/M9000 Servers Service Manual June 2010
20. Start (turn on power) all domains together. Take either of the following two
actions:
Press and hold down (for less than four seconds) the POWER switch on the
operator panel.
From the console that is connected to XSCF, execute the
poweron -d <domain-id> command of XSCF for the domain of the swap
target new CMU.
Power to all the domains is turned on. Firmware version synchronization of the
target domain is automatically performed.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On”
on page 4-19, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF User’s Guide.
21. Using the XSCF version command, confirm that the firmware version of the
target domain is the same in the replacement CMU.
For details of firmware version synchronization, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide.
22. Confirm that the replacement components are normal by using the
showhardconf or showstatus command of XSCF.
Unless "*" is displayed for a replacement CMU, CPU, or DIMM, it is operating
normally.
For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide,
the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual, or the man page.
Note – The showstatus command displays information on degraded components.
23. Restore the original mode switch setting on the operator panel.
Note – When the maintenance work is completed, be sure to confirm the mode
switch setting and return the switch to Locked.
24. Close the door on the server, and lock it.