Fujitsu M9000 Server User Manual


 
21-1
CHAPTER
21
Sensor Unit Replacement
This chapter explains the replacement procedure for the sensor unit (SNSU). It
covers the following:
Section 21.1, “Overview of the SNSU” on page 21-1
Section 21.2, “Cold Replacement” on page 21-4
As a replacement method for the SNSU, only the cold replacement method can be
used. For the definition of the replacement method, see Section 4.1, “Types of
Replacement Procedures” on page 4-2.
21.1 Overview of the SNSU
This section provides an overview of the SNSU and describes its mounting locations.
The sensor unit monitors the temperature and humidity of air drawn in by the
server. The sensor unit consists of only a detecting element, and the controller block
is built in to the operator panel. Active maintenance cannot be performed on the
SNSU.
FIGURE 21-1, FIGURE 21-2, and FIGURE 21-3 show the mounting locations of the SNSUs
of SPARC Enterprise M8000 server, SPARC Enterprise M9000 server (base cabinet),
and the base cabinet of SPARC Enterprise M9000 server with the expansion cabinet
respectively.