Appendix E XSCF Unit Replacement When XCP 1040 or 1041 Is in the Server E-3
19. Confirm switching over between XSCFs works properly.
a. When the READY LED on XSCFU_B#1 remains lit, log in to XSCFU#0 using
a serial connection or LAN connection.
b. Confirm switching over between XSCFs using the following commands:
Confirm XSCFU#1 is now the standby, and that XSCFU#0 has become the active.
Confirm no new errors have been recorded since the check in Step 14.
Confirm a message "XSCFU entered active state from standby state".
Confirm a message “No failures found in System Initialization”.
20. Power on all domains.
21. Log in to XSCFU#0 and confirm all domains start up properly.
22. Check that there are no new errors.
■ In case an abnormality is encountered, take appropriate maintenance action and
contact service engineer.
■ If no abnormality is found, proceed to Step 23.
XSCF> switchscf -t Standby
The XSCF unit switch between the Active and Standby states.
Continue? [y|n] :y
XSCF> showhardconf
XSCF> showlogs error
XSCF> showlogs event
XSCF> showstatus
XSCF> poweron -a
XSCF> showlogs power
XSCF> showlogs error