Fujitsu MBA3147RC Computer Drive User Manual


 
Parameter Data Format
5.1.1 Read/Write Error Recovery Parameters (Page Code = 1)
Table 5.1 lists the format of the page descriptor of this MODE SELECT parameter.
Table 5.1 MODE SELECT parameters: read/write error recovery parameters
Bit
Byte
7 6 5 4 3 2 1 0
0 0 0 0 0 0 0 0 1
1 X'0A' (Page Length)
2 AWRE ARRE TB RC ERR PER DTE DCR
Default 1 1 0 0 1 0 0 0
Variable 1 1 1 1 1 1 1 1
3 READ RETRY COUNT
Default X'3F'
Variable X'FF'
4 Correctable Bit Length
Default X'FF'
Variable X'00'
5 X'00' (Head Offset Count)
6 X'00' (Data Strobe Offset Count)
7 X'00' (Reserved)
8 WRITE RETRY COUNT
Default X'3F'
Variable X'FF'
9 X'00' (Reserved)
10-11 Recovery Time Limit
Default X'7530'
Variable X'FFFF'
(=63
times)
(=255 bits
or more)
(=30s)
(=63
times
)
282 C141-C013