C156-E142-02EN 2 - 7
2.1.3 Environmental and power requirements
Table 2.3 lists the environmental and power requirements.
Table 2.3 Environmental and power requirements (1 of 2)
Item Specification
Power
requirements
Average +5 VDC±5%, 1.1 A (2.5 A Max.) (*1)
Ripple requirement 100mV P-P (DC-1 MHz)
MCE3130AP MCE3064AP, MCF3064AP
Ready 3.9 W (typical) (*2) 3.9 W (typical) (*2)
Random seek, read/ or write 5.5 W (typical) (*2) 5.3 W (typical) (*2)
Power save mode
Pre-idle mode
Idle mode
Standby mode
Sleep mode
3.40 W (typical) (*2)
2.00 W (typical) (*2)
0.65 W (typical) (*2)
0.65 W (typical) (*2)
3.40 W (typical) (*2)
2.00 W (typical) (*2)
0.65 W (typical) (*2)
0.65 W (typical) (*2)
With panel
101.6"150.0"25.4 mm
Without panel
101.6"148.4"25.4 mm
Weight 480 g (with panel)
Environmental
requirements
Operating Temperature: 5 to 45°C (*3)
(gradient 15°C /h or less)
Relative humidity: 10 to 85% (Noncondensing)
Max. wet bulb temperature: 29°C or lower
Idle Temperature: 0 to 50°C
Relative humidity: 10 to 85% (Noncondensing)
Max. wet bulb temperature: 36°C or lower
Transport Temperature: –40 to 60°C (24 hours or less)
Temperature: –20 to 60°C (24 hours or more)
Relative humidity: 5 to 90% (Noncondensing)
Max. wet bulb temperature: 41°C or lower
Requirement: Packing conditions specified by Fujitsu
Installation Tilt angle –5° to +10° (*3)
Vibration/
shock
Operating 3.92 m/s
2
(0.4 G [5 to 500 Hz, sine sweep])
Shock 19.6 m/s
2
(2 G [10ms, half-sine pulse])
Idle
No cartridge, power ON
9.8 m/s
2
(1.0 G [5 to 500 Hz, sine sweep])
Shock 49 m/s
2
(5 G [10 ms, half-sine pulse])
Transport Shock 490 m/s
2
(50 G [10 ms, half-sine pulse])
Requirement: Packing conditions specified by Fujitsu
Power
consumption
Dimensions
(W"D"H)