Fujitsu MCM3130SS Computer Drive User Manual


 
Specifications
2-4 C156-E228-02EN
2.1.3 Environmental and power requirements
Table 2.3 lists the environmental and power requirements.
Table 2.3 Environmental and power requirements (1 of 2)
Item Specification
Power
requirements
Average +5 VDC±5% (*1), 1.2A (2.7A max)
Ripple requirement 100mV pp (DC-1 MHz)
Power Ready 3.9 W (typ) (*2)
consumption Random seek, read or write 6.1 W (typ) (*2)
(Average) Power save
mode
Pre-idle mode
Idle mode
Standby mode
Sleep mode
3.9 W (typ) (*2)
2.0 W (typ) (*2)
1.2 W (typ) (*2)
1.2 W (typ) (*2)
Outer
dimensions
With panel 101.6×150.0×25.4 mm
(W × D × H) Without panel 101.6×148.4×25.4 mm
Weight 410 g (with panel)
Environmental
requirements
Operating Temperature: 5 to 45°C (gradient 15°C /h or less)
(*3)
Relative humidity: 10 to 85% (No condensation)
Maximum wet bulb temperature: 29°C or lower
Idle Temperature: 0 to 50°C
Relative humidity: 10 to 85% (No condensation)
Maximum wet bulb temperature: 36°C or lower
Transport Temperature: –40 to 60°C (24 hours or less)
Temperature: –20 to 60°C (24 hours or more)
Relative humidity: 5 to 90% (No condensation)
Maximum wet bulb temperature: 41°C or lower
Installation Tilt angle –5° to +10° (*3)