Furuno IB-681 Network Router User Manual


 
3
2. SETTINGS
2.1 Switch Panel Settings
Communication parameters are set with the switches in the switch panel. Unfasten two
screws to access the switches. Note that it is not necessary to turn off the IB-681 to
access the switches.
ON
1 2 3 4
5 6 7 8
Data Rate
64K
56K
: Factory setting
Figure 3 Switch panel
2.1.1 Data rate
Set the data rate according to land line/network. The default setting is 64k (64 Kbps). 56k
is for USA ISDN circuit, for example. Data rate cannot be change after connecting with a
subscriber.
2.1.2 DIP switches
Table 1 DIP switch functions
.oNWSnoitcnuFFFONO
1WSllaccitamotuAllactceriDllacsserddA
2WSecafretnilanimreT944-SR232-SR
3WS
atadcitamotuA
gnihctiwsetar
ONSEY
4WStamrofdnammoCCLDHCSB
5WStamrofretcarahCytirapon/tib8ytirapddo/tib7
6WSdesutoN
7WSdesutoN
8WSdesutoN
SW1: Automatic call mode
OFF: Call starts with reception of DTR signal from HSD terminal.