Furuno MODEL CSH-73 Scanner User Manual


 
6-3
Function Key Fine Tuning
Fine
Adjustment
Item
-4 -3 -2 -1 0 1 2 3 4 5
TVG Near -3 -2 -1 0 0 1 1 2 3 4
TVG Mid -3 -2 -1 0 0 0 1 1 2 3
TVG Far -3 -2 -1 0 0 0 0 1 1 2
Tx Cycle 0 0 0 0 0 0 0 0 0 0
Tx Beamwidth -3 -2 -1 0 0 0 0 0 0 0
Tx Power -2 -1 0 0 0 0 0 0 0 0
Saving Function Key Settings to a Memory Card
1. Press the MENU key.
2. Select the CARD UTILITY menu.
CARD UTILITY Press END key to return to main menu.
List Execute
Save Execute
Delete Execute
Initialize Execute
Figure 6-2 CARD UTILITY menu
3. Select Save and press the MENU key.
Note: If the card has not been initialized, initialize the card by
selecting Initialize and then save.
Replaying Function Key Settings from a Memory Card
Press the CARD REPLAY key on sub panel 1.
Note: When function key settings are replayed from a memory
card, current settings on all function keys are erased. Therefore,
if necessary, save current function key settings to another memory
card before replaying.